Description
Specifications
Presentation | Double-conversion On-line UPS with Lithium-Ion battery to scalable runtime. Ideal UPS for essential power protection needs even in the most unstable power conditions. |
---|---|
Lead time | Usually in sufficient supply |
Run time for load
W
Min-max: 90-900 W
|
2h 16min |
---|---|
|
|
Main Input Voltage | 230V |
Other Input Voltage | 230 V |
Main Output Voltage | 230V |
Other Output Voltage | 220 V 240 V |
Rated power [W] | 900W |
Rated power [VA] | 1000VA |
Input Connection Type | IEC 60320 C14 |
output connection type | 6 IEC 60320 C13 |
Number of rack units | 4U |
Equipment provided | Basic UPS Signal RS-232 Cable USB cable RJ45 cable RJ11 cable C13-C14 power cord IEC-C14 - Shuko input power cord rack mount bracket stabilization feet User Manual Safety Guide Battery cable |
Run Time | View Runtime Graph |
---|---|
Efficiency | View Efficiency Graph |
Battery Type | Li-Ion (lithium ion) |
voltage | 48V |
Pre-installed battery | 0 |
Empty battery slot | 0 |
Typical charging time | 8.5 hours |
battery life | 8…10 years |
Battery charging power (watts) | 240W |
Number of power module filled slots | 0 |
---|---|
Number of power module free slots | 0 |
Redundant | No |
color | Black with silver front bezel |
---|---|
high | 17.2 cm |
width | 43.8cm |
depth | 61.6cm |
product weight | 36.3kg |
USB compatible | Yes |
Installation location | horizontal and vertical orientation |
Efficiency at full load |
160...300 V full load 110...300V 60% load |
---|---|
Network frequency | 40...70 Hz auto-sensing |
Maximum configurable power in VA | 1000VA |
---|---|
Maximum configurable power (W) | 900W |
Output frequency (synchronized with mains) | 50/60 Hz +/- 3 Hz synchronized with mains |
topology | Online double conversion |
Wave type | sine wave |
Efficiency at full load | 90% full load) |
bypass type | Internal bypass (automatic vs. manual) |
Crest coefficient | 3:1 |
Product certification | IEC CB report CE RCM EAC TISI UKCA KC UN 38.3 IEC 62619 |
---|
Working temperature | 0…40°C |
---|---|
Relative humidity | 0…95 % non-condensing |
operating height | 0...3000 m |
Storage environment temperature | -20…50 °C |
relative storage humidity | 0…95 % non-condensing |
Storage height | 0…15000 m |
sound level | 50dBA |
heat dissipation | 341W |
IP protection level | IP20 |
alarm | Alarm when on battery: distinctive low battery alarm: overload continuous tone alarm |
---|---|
Emergency power off (EPO) | Yes |
Alarm function | Multifunctional LCD status and control console |
surge absorption capacity | 945J |
---|
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 48cm |
Package 1 Width | 80cm |
Package 1 Length | 60 cm |
Package 1 Weight | 48.82kg |
maintainance | 3 years UPS repair or replace; 5 years battery repair or replace |
---|